Directed Sensor, Glasbruch

1506T_D1.jpg
€41.18 *

Prices incl. VAT plus shipping costs

available,
Delivery time appr. 1-2 working days

Seen cheaper?
Quantity
Artikel günstiger gesehen?
  • 02074506T
  • 93207005060
A hidden microphone installed analyzed the frequency, intensity  and the timing of all notes in... more
Product information "Directed Sensor, Glasbruch"
A hidden microphone installed analyzed the frequency, intensity
 and the timing of all notes in the vehicle. The spectral properties of a
recorded noise are evaluated by a microprocessor.
In recognition is typical properties of Berstgeräusches of glass
Alarm is triggered. This technology works absolutely false-alarm free.
Advantages of the system:- Inexpensive sensor - Easy installation - Minimum
 Costs for cabling - Very high immunity to false alarms Important
Note:If you are the more alarm sensors to an alarm input
Wish to connect alarm system, you must each alarm line with a
 Blocking diode (sold separately) decouple. It can otherwise
False alarms occur.


CONNECTIONS
 - Red:Connect the red wire of the 3-pin connector with permanent 12V.

 - Black:Connect the black wire of the 3-pin connector with
Mass or the "mass when Armed" port of your alarm system.
                  
 - Blue:Connect the blue wire from the 3-pin connector with the (-) alarm input on your alarm system.


INSTALLATION

 - Choose a good installation, for example, under the headliner or
over the monitoring at the wheel, for optimal functioning of the
Sensor. Avoid them close to loud engines, compressors or
Fans. Determine the exact position and orientation of the 506T so,
that the microphone side of the sensor an unobstructed view of the
monitored disks has. Do not place anything or harnesses
obscure the detection angle of the sensor.


SETTINGS

 - Adjust the sensitivity using the small knob to the
 Housing. Make a noise with a bunch of keys to the
To check setting. A ticker with a coin on a
Vehicle window should trigger an alarm. The red LED lights up
whenever the sensor triggers an alarm.
 

SPECIFICATIONS
 - Operating voltage:DC 9-15V
 - Power consumption:0.001A (average value during normal operation)
 - Temperature range:-40 ° C ~ + 85 ° C
 - Output signal:negative pulse of 0.5 seconds (short-circuit protection)
quantity: 1 piece
Product group: sensors
Related links to "Directed Sensor, Glasbruch"
Read, write and discuss reviews... more
Customer evaluation for "Directed Sensor, Glasbruch"
Write an evaluation
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.

I have read the data protection information.

Viewed